This article will give fire door maintenance tips.
As a first time investor or a business owner, it is important to have your own building for your employees. Instead of renting which will double the cost, experts will suggest to purchase and construct your own building. During the construction, it is important to put in mind the safety of all who will use the facility. Professionals will encourage you to put fire doors and other safety related equipment and plan. There are kinds of fire doors that come in altered standard span of time frame and it depends on the building size that needs protection. If you have a small unit, then a 30-minutes standard span of time frame is good for the people to use as their escape. For a bigger one, the building will need a 45, 60 to 90 minutes span of time kind of fire door that can withstand the high temperature caused by the fire incident. During the incident, the people can go out and escape with the help of these fire doors and will also help the rescuers find and put out the fire easily and quickly. When you want to make sure that your fire doors are completely working, always check on these:
Intact vision light frames, glazing and glazing beads
All of these things must be properly in place and should be accurately fastened. It is recommended to be inspected always to see if one these are missing.
No missing parts
When you opt for a fire door inspection and when the inspector would find out that there is a missing part, then they will endorse it for repair or change of materials. This thing should be done immediately for safety reasons.
Proper measurement of door clearance
If the company is about to put the fire door into an inspection process, then the inspector should locate the proper clearance and if it will not meet the standards set by the government, then a repair of the clearance will be advised for it to function properly. If the clearance of the door is not proper, then the capacity of the door to work will fail due to the seal of the door will not cover all the gaps when there is a fire.
Aligned frame, door and hinges
As we can see, there are some components that are non-combustible and will function with the right signs of breakage or damage. These fire rated doors must always be correctly fitted in order to avoid the leakage of fire from one place to another.
Surface of the door and frame
Always check that the surface of the door will not have hole or breaks for it will make the door less fire proof. Experts say that a fire only needs a small crack or hole for it to penetrate the other part of the door. If this thing occurs, then it will be a unserviceable protective door. Always remember that the fire door is only coated with a special material and can withstand a high temperature for just a small period of time and will eventually burn down after a while.